Zusammenfassung
An accurate position of the isocenter of a cone-beam CT trajectory is mandatory for accurate image reconstruction. For analytical backprojection algorithms, it is assumed that the X-ray source moves on a perfectly circular trajectory, which is not true for most practical clinical trajectories due to mechanical instabilities. Besides, the exibility of novel robotic C-arm systems enables new trajectories where the computation of the isocenter might not be straight forward. An inaccurate isocenter position directly affects the computation of the redundancy weights and consequently affects the reconstructions immediately. In this work, we compare different methods for computing the isocenter of a non-ideal circular scan trajectory and evaluate their robustness in the presence of noise. The best results were achieved using a method based on a least-square-based fit. Furthermore, we show that an inaccurate isocenter computation can lead to artifacts in the reconstruction result. Therefore, this work highlights the importance of an accurate isocenter computation with the background of novel upcoming clinical trajectories.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
Similar content being viewed by others
Literatur
Maier A, Choi JH, Keil A, et al.; International Society for Optics; Photonics. Analysis of vertical and horizontal circular C-arm trajectories. Phys Med Imaging. 2011;7961:796123.
Jia F, Li Y, Xu H, et al.; IEEE. A simple method to calibrate projection matrix of c-arm cone-beam ct. Proc Biomed Eng Biotech. 2012; p. 682–685.
Feldkamp LA, Davis L, Kress JW. Practical cone-beam algorithm. Josa A. 1984;1(6):612–619.
Parker DL. Optimal short scan convolution reconstruction for fan beam CT. Med Phys. 1982;9(2):254–257.
Maier J, Black M, Bonaretti S, et al. Comparison of different approaches for measuring tibial cartilage thickness. J Integ Bioinf. 2017;14(2).
Navab N, Bani-Hashemi A, Nadar MS, et al.; Springer. 3D reconstruction from projection matrices in a C-arm based 3D-angiography system. Int Conf Med Image Comput Comput-Assist Interv. 1998; p. 119–129.
Hartley R, Zisserman A. Multiple View Geometry in Computer Vision. Cambridge University Press; 2003.
Choi JH, Maier A, Keil A, et al. Fiducial marker-based correction for involuntary motion in weight-bearing C-arm CT scanning of knees. II. experiment. Med Phys. 2014;41.
Fieselmann A, Ritschl L. Isocenter determination for arbitrary planar cone-beam CT scan trajectories. Proc Intl Mtg Image Form. 2016; p. 241–4.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2019 Springer Fachmedien Wiesbaden GmbH, ein Teil von Springer Nature
About this paper
Cite this paper
Amri, A., Bier, B., Maier, J., Maier, A. (2019). Isocenter Determination from Projection Matrices of a C-Arm CBCT. In: Handels, H., Deserno, T., Maier, A., Maier-Hein, K., Palm, C., Tolxdorff, T. (eds) Bildverarbeitung für die Medizin 2019. Informatik aktuell. Springer Vieweg, Wiesbaden. https://doi.org/10.1007/978-3-658-25326-4_61
Download citation
DOI: https://doi.org/10.1007/978-3-658-25326-4_61
Published:
Publisher Name: Springer Vieweg, Wiesbaden
Print ISBN: 978-3-658-25325-7
Online ISBN: 978-3-658-25326-4
eBook Packages: Computer Science and Engineering (German Language)